Additional information
Origin | Mainland China |
---|---|
Feature | Stocked |
Model Number | Commercial stove infrared anti - air burning controller |
Material | Plastic |
Plastic Type | Melamine |
Type | Kitchen Lighters |
Certification | CE / EU |
177.50 $
50 in stock
Origin | Mainland China |
---|---|
Feature | Stocked |
Model Number | Commercial stove infrared anti - air burning controller |
Material | Plastic |
Plastic Type | Melamine |
Type | Kitchen Lighters |
Certification | CE / EU |
Commercial stove infrared anti-air burning controller function description
The controller is a commercial stove controller without fan control the fan can be independently controlled, which can realize automatic high-energy ignition and anti-air burning, and meet the needs of automatic control and safety protection of modern kitchen stoves. Controller working process:
The controller turns on the power switch, starts ignition, opens the air valve, and after 12 seconds, the ignition stops and enters the combustion state. At this time, the infrared sensor head and the receiving head constitute a pot sensor to detect whether there is a pot on the furnace, such as infrared light is blocked. It means that there is a pot to keep the burning state, otherwise the gas valve is closed and the flame is extinguished to prevent air burning. After that, the pots were monitored at any time, and there were pots and no pots. Function Description 1. High-energy ignition, sparks like open flames.
2. Prevent empty burning waste, automatically turn off the oil off the pot, put the pot to automatically send oil to ignite.
3, 24V gas solenoid valve with emergency switch, can be opened for continued use in case of accident. Installation Notes
1. Determine the installation position of the control box according to the length of the lead wire. It is recommended to install it on the iron frame behind the front plate of the furnace to avoid the high temperature area as much as possible.
2. Install the gas solenoid valve horizontally and keep the solenoid valve away from the high temperature zone.
3. Ignition pin installation method: double-needle ignition two-pin furnace fires each other, installed near the air outlet.
4. Installation of infrared emission and reception. Controller related connection:
1. Connect the power cable to 220V AC power supply. Set the power switch to start or stop the work. Turn off the power when not in use.
2. The ignition wire is connected to the ignition pin for ignition. The ignition pin is recommended to be in the form of a double point, which is most beneficial for the stable operation of the controller. If the single-fired burner is used, it will increase the probability of the controller being disturbed, so we do not encourage it. Be sure to reliably ground one of the high voltage wires when the customer must use it.
3. A 24V gas solenoid valve is connected to the solenoid valve line to control the total oil circuit of the stove.
4. Two-core waterproof plug is connected to the infrared emitter.
5. Four-core waterproof plug is connected to the infrared receiver.
6. In view of the harsh working environment of commercial stoves, in order to ensure long-term reliable operation of the controller, it is strongly recommended to take the waterproof and anti-fouling work of each wire joint seriously. After the debugging, the exposed wires and joints are wound with a wrap and a plastic wrap. Insulating tape and the like are tightly wound.
Installation instructions for the transmitter and receiver:
1. First, on the left side of the front beam of the furnace surface, first open the Φ20mm hole from the edge of 6-10cm. After the middle hole of the base is aligned with the opened hole, open the hole of the fixed base and fix the base of the emitter with the rivet. Insert the emitter into the hole, adjust the direction and fix the emitter with screws.
2. Drill the base of the emitter with a rivet according to the shape of the emitter;
3. Fix the receiving head on the back plate. Different hobs have different fixed positions, generally installed as follows;
a. Avoid the high temperature area of the exhaust vent and the high temperature area on the back of the stove;
b. The optical path of the transmitting head and the receiving head passes through the center point of the furnace
c. The optical path connection between the transmitting head and the receiving head cannot be blocked by the height of the furnace, and the nearest distance is 1-2 cm higher than the furnace;
d. Place the pot on the pan holder and do not block the light path connection between the emitter and the receiving head; at this time, the light path connection should be 2~4CM in front of the pot.
4. Open the Φ20mm hole at the selected position on the back plate. After the middle hole of the base is aligned with the hole opened, open the hole of the fixed base, fix the base of the receiving head with the pull stud, insert the receiving head into the hole, and adjust it. Then fix the receiving head with screws.
5. If two sets of controllers are installed on the double-head hob, the left and right sides are symmetrically installed. The two receiving heads are in the middle and the two transmitting heads are on both sides. Commissioning instructions for the controller:
1. Commission the power after installing all components. Infrared radiation debugging:
A. The upper part of the aluminum infrared component has a small eye. The function is to emit a beam of infrared light that is invisible to the naked eye to the receiving head to detect whether there is a pot on the stove. When there is a pot, the light will be blocked and the receiving head will not be received, otherwise an infrared signal will be received. This infrared ray is modulated and will not be confused with other infrared rays in the environment. The receiving head will clearly filter out this effective signal to achieve a correct judgment on the existence of the pot.
B. The aluminum infrared component has a glass window at the side end, which is a receiving head, built-in infrared receiving component and status indicator. The light is always on, indicating that the correct infrared signal is received, indicating that the infrared light is not blocked, and the transmitting and receiving directions are basically Normal, within the valid range. On the contrary, the flashing of the light indicates that the infrared signal is not received, indicating that the infrared light is blocked or emitted by the cookware, and the receiving direction is not within the effective range.
C, adjust the transmitting head to make the transmitting head emit in the direction of the receiving head. At this time, the infrared emitting head is blocked, the receiving head red light flashes, indicating that the receiving head controller is ignited, the electromagnetic valve is opened, and the receiving head is red when removed. Always bright. Precautions:
1. In the state of power or ventilation, the operator or other personnel are strictly prohibited to use the head or other body parts close to the burner, or block the light path to avoid fire burns. When it is necessary to check for fire, the fan must be turned on;
2. Under the working condition, it is strictly forbidden to place other items in the light path, so as to prevent the light path from being out of control.
3. To better experience the performance of this product, periodically wipe the transmitter and receiver with a soft object such as a sponge.
4. Cover the receiver's transmitter with something when cleaning the stove to prevent hard objects from getting scratched or water.
5. For everyone's safety, always close the main valve when not using the stove! ! !
6, commercial stove igniter – lead wire connection description: two high-voltage ignition wire 800mm with double-needle ignition needle for relative ignition, or a high-voltage ignition wire 800mm with ignition needle, and another high-voltage ignition wire 800mm The furnace body, the distance between the ignition needle and the metal of the burner is 5-6mm, and the ignition is discharged for the burner to form an ignition circuit. Ignition high-voltage line connection: The company strongly recommends that the customer use the dual-purpose ignition for the ignition needle. This kind of ignition effect is better. If the double-needle can only be used with a single needle because of the burner, one of the high-voltage output leads 800mm Connect the ceramic ignition needle, another high-voltage output lead 800mm must be fixed on the burner with screws. The distance between the ignition needle and the metal of the burner is 5-6mm. The ignition is discharged against the burner to form an ignition circuit. Note that it is not on the stove, it is not attached to the hob. If it is connected to the hob, the ignition circuit is very long. Moreover, the hob and the burner are not necessarily connected, so the ignition is cut off. In the loop, the igniter only uses half the power. Maybe you can hardly understand the truth at the same time. Maybe you will say that I have been connected in this way. It is very good. You just have to try it. So the igniter output high voltage line produced by our company is double long line. Length 800mm,
Infrared anti-air burning controller installation precautions
1. The installer must have an electrician installation qualification.
2. The rated input voltage of this igniter is 220V 50HZ. A qualified leakage circuit breaker must be installed at the front end of the power supply. The metal casing of the cooker must be protected by a grounding wire. It is strictly forbidden to connect the metal casing with a neutral wire!
3. The control switch on the panel should use a bipolar power switch of not less than 5A/250V, and the igniter power cord is connected to the power switch.
4. The controller can be fixed or suspended in the lower space of the cooker, and should avoid high temperature radiation baking.
5. High-voltage line is connected to the ignition needle. It is recommended to use dual-ignition ignition mode. The discharge spacing of the ignition needle is 3-5mm. Try not to use the single-discharge method. If only one high-voltage line is connected to the ignition needle, the other high-voltage line must be reliably connected to the burner. On the metal body, it can not be easily connected to the metal casing of the cooker, which will bring many difficult problems!
6. The length of the high-voltage line is “sufficiently long and shortest”. It is better to separate the two lines by more than 3 cm, and maintain a certain degree of drooping arc to facilitate oil drop. The high-voltage line can not be extended continuously. The wiring is not allowed to be close to the iron frame and iron plate of the stove. Do not add all kinds of casings. It is absolutely necessary to avoid twisting the two high-voltage wires together to avoid high-frequency high-voltage leakage.
7. Regularly clean up debris and do not rinse with water.
1. Description of N series atomization controller This series of controllers are used in conjunction with methanol spray burners to complete ignition and firepower adjustment. The ones with extinguishing function can be used in steaming ladle furnaces and other places. System parameter setting method: Long press the setting key to enter the system parameter setting, turn the knob to select the desired menu, then press the setting key to display the value, turn the knob to adjust the value, and then long press the setting key until SAU is displayed, which means the save is successful. Note: If you don't [...]
80.53 $ Add to cartBasic parameters of DQ8B commercial stove super igniter The DQ8B super igniter developed and produced by our company is an AC220V igniter, which can ignite cigarettes within 1 second, with stable and reliable performance and high ignition efficiency. Widely used in commercial equipment such as hotel energy-saving stoves, boilers, burners, steam cabinets, ovens, etc. fueled by diesel, gasoline, alcohol, biofuels, and various industrial oils. Since it was launched on the market in 2010, it has been widely loved by customers, and now customers are all over the Pearl River Delta and the whole country. 1. Product model: DQ8B. 2. Main [...]
83.75 $ Add to cartHW-103 igniter: also known as industrial furnace pulse ignition controller, this product is mainly used for ignition and control of various industrial equipment and hotel stoves using liquefied gas, natural gas, artificial gas. Power-on ignition or switch-controlled ignition accidental flameout key ignition function, ion flame automatic monitoring function and flameout alarm, ignition failure and accidental flameout automatically cut off gas source safety protection, using microcomputer digital control technology, using lightning protection technology Power-on ignition/switch Control the ignition, stop the ignition after the flame is automatically detected, the solenoid valve keeps the combustion indicator light on, and when the ignition time [...]
92.50 $ Add to cartFully compatible with the general-purpose OCE-K339L controller, the materials are more sophisticated, the performance is more stable, and the anti-interference is stronger. Upgrade does not increase the price, if our improvement can improve your quality, I DO. 1. Plate upgrade: It adopts Aobolai KB Class A FR4 glass fiber board, which has better electrical performance and higher safety. 2, process upgrade: SMD surface patch technology, double-sided wiring design, automatic production efficiency, more stable performance; buzzer built-in, to avoid collision during transportation and use the housing to expand the sound, the sound is louder. 3, program upgrade: the main control chip [...]
115.00 $ Add to cartFunctional description of infrared anti-air burning controller for commercial stoves This controller is used on commercial gas stoves, which can realize infrared control. Controller working process: Turn on the power switch, the controller starts to ignite, and the solenoid valve is opened at the same time. After 12 seconds, the ignition stops and enters the burning state. At this time, the pot sensor composed of the infrared emitting head and the receiving head detects whether there is a pot on the stove, such as If the infrared light is blocked, it means there is a pot and keep the burning [...]
121.25 $ Add to cartFunction description of alcohol-based fuel vaporization controller for precise regulation of firepower The controller is used for electric heating and alcohol-free gasification stove without fan, in addition to the functions of conventional heating, temperature measurement, temperature control, ignition, electromagnetic pump speed regulation, etc., it can also expand external precision regulator to achieve precise adjustment of oil pump flow and Start-stop control, this function and gear position adjustment achieve the effect of no need to switch, fire with heart, start and stop freely. At the same time, it can also extend the external word reset rocker switch or the third gear [...]
415.00 $ Add to cartFunction description of alcohol-based fuel vaporization controller for precise regulation of firepower The controller is used for electric heating and alcohol-free gasification stove without fan, in addition to the functions of conventional heating, temperature measurement, temperature control, ignition, electromagnetic pump speed regulation, etc., it can also expand external precision regulator to achieve precise adjustment of oil pump flow and Start-stop control, this function and gear position adjustment achieve the effect of no need to switch, fire with heart, start and stop freely. At the same time, it can also extend the external word reset rocker switch or the third gear [...]
477.50 $ Add to cartDHLG12 Single-head Pulse Igniter Battery Firing Double-headed Firearm For Gas Features: Brand new and high quality Made of high quality material, durable and wear-resistant Easy to use stable performance Installation and use of A1 igniter: 1. It is necessary to drill a hole of 18mm on the stove panel for installation. Installation on the stove panel is equivalent to grounding and will not be electric. 2. Press the cover to fire continuously. If you dont press it, it will not fire. There will be sparks within 1CM of the ignition needle close to the metal body burner head Specification: [...]
BBQ Gas Grill Replacement 2 Outlet AA Battery Push Button Ignitor Igniter Blackbrand new and high qualityMaterial: Metal & PlasticColor: BlackFeature:1. Electric 2 Outlet Push Button Ignitor2.Suitable for BBQ Gas Grill Replacement3.Power supply: 1 x “AA” batterybattery is not includedbattery is not included4.Voltage: for DC 1.5V5.Size: 7.5 x 3 x 7cm Quantity:1 PCNote: Please allow 1-2cm error due make sure you do not mind before you bid.Due to the difference between different monitors, the picture may not reflect the actual [...]
Features: Durable: The gas stove knob is made of high quality zinc alloy material, which is tough, hard, wear resistant and durable , owning long using life span. Easy to operate: The gas stove knob with a raised handle is convenient to hold tightly and operate. Compact: The gas stove knob is compact and lightweight, convenient to storage and will not occupy much storage space. Scope of application: The gas stove knob with 8mm axis hole is widely suitable for most gas stoves. Specification: Type: gas stove knob Quantity: 1pc Material: zinc alloy Color: silver Diameter: 4cm/ 1.57inch Height: 2cm/ [...]
Newly USB Rechargeable Electric Arc Lighter Windproof Flameless Flexible for Home Kitchen BBQ Description: Features: 1. Safety design:This arc lighter is designed with 10cm longest 360 degree flexible neck, it can bend to different angles to meet your different needs. Long flexible neck keeps a safe distance from your hand, 8 seconds automatically turn off feature ensures a safety use that prevents too high temperature damage. 2.LED Battery Display:The upgraded candle lighter can display real battery volume. A fully charge can be filled within 1-2 hours with 4 LED lights all turn on. This USB lighter can offer [...]
body,td,th { font-family: Verdana, Geneva, sans-serif; font-size: 16px; color: #636363; } body { margin-left: 0px; margin-top: 0px; margin-right: 0px; margin-bottom: 0px; } a{ color: #636363; text-decoration: none; } a:hover { text-decoration: none; color: #636363; } a:active { text-decoration: none; color: #636363; } em { color: #BD1A1D; font-style: normal; font-weight: 700; } Culinary Torch Lighter Refillable Flamethrower Kitchen Cooking Torch with Adjustable Flame Safety Lock for BBQ Crafts LOTE88 Features: 1. Application - Great for flame, baking cake, seafood, melting cheeses and chocolates, bar cocktails, lighting a fire, cigars, BBQ , camping, jewelry making [...]
ZQ1 alcohol based fuel steam controller system description First, the configuration: 220V electromagnetic pump; 220V fan; super ignition; start button compatible switch; wind pressure switch; lower water level probe; ignition needle; fire needle; status indicator. Second, the applicable products: Alcohol based fuel steam generator Third, the work process: When the start button is turned on, the fan runs immediately. When the wind pressure switch is turned on, the ignition starts and the 220V electromagnetic pump is started, and the alcohol-based fuel is sprayed. When the fire detector detects the flame controller, the ignition is stopped, and the system enters the [...]
96.25 $ Add to cartChcę coś kupić ale szukam informacji jak zamówić... |
Kupiłem coś ale chcę poznać status zamówienia... |
Odebrałem paczkę ale mam pytanie lub problem... |
Chcę dokonać zwrotu i potrzebuję informacji... |
Droptech Sp. z o.o. droptech.polska@gmail.com |
ul. Łódzka 118, Piotrków Tryb. Sprzedajemy tylko przez internet |
NIP: 7712911090 REGON 386758083 |
Wysyłka bezpośrednio od producenta lub dostawcy |
DARMOWA WYSYŁKA + ubezpiecznie dostawy + śledzenie przesyłki |
CAŁKOWITY ZWROT podczas reklamacji |
Reviews
There are no reviews yet.